All

KAN-LF-01 - 디지털 열식 액체 질량 유량계(Mass Flow Meter)

Liquid Mass Flow Meters for low ow rates 

Bronkhorst model KAN-LF-01 Liquid Flow Meters are suited for precise measurement of ow ranges between 0.1~5ul/s at operating pressuresup to 100 bar. The LFM consists of a thermal mass ow sensor and a microprocessor based pc-board with signal and eldbus conversion and a PID controller foroptional mass ow control by means of a separately mounted control valve. 


LIQUI-FLOW™ series are equipped with a digital pc-board, offering high accuracy, excellent temperature stability and fast response. The main digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output the instruments also offer analog I/O. As an option, an on-board interface can be mounted to provide CANopen®, DeviceNet™, EtherCAT®, PROFIBUS DP, PROFINET, Modbus RTU, ASCII or TCP/IP, EtherNet/IP, POWERLINK or FLOW-BUS protocols. 


Technical speci cations 


Measurement / control system

Flow range ( ranges available )                                         0.1 ~ 5ml/s (based on H O)

--------------------------------------------------------------------------------------------------------------------

Accuracy (incl. linearity) (based on actual calibration)                       ± 1 % FS

--------------------------------------------------------------------------------------------------------------------

Repeatability                                                                            < 0,2 % FS (typical H O)

--------------------------------------------------------------------------------------------------------------------

Operating temperature                                                                                   5 … 50 °C

--------------------------------------------------------------------------------------------------------------------

Temperature sensitivity                                                                             ± 0,1% FS/°C

--------------------------------------------------------------------------------------------------------------------

Attitude sensitivity                                                                                         negligible

--------------------------------------------------------------------------------------------------------------------

Warm-up time                                                               30 min. for optimum accuracy; 

                                                                                            2 min for accuracy ± 2% FS

--------------------------------------------------------------------------------------------------------------------



​​​